SSi PGA 3510 Portable Three Gas Analyser (CO, CO2, CH4)
Portable infrared analyser measuring CO, CO2 and CH4 for verifying, optimising and troubleshooting furnace and generator atmospheres.
Analysers and meters
Portable dew point analyser used to optimise the air to gas ratio and trim settings on endothermic generators and carburising furnaces.
The DP2000 is a simple but highly effective portable dew point analyser used to optimise the air:gas ratio and trim settings on endothermic generators and carburising furnaces.
The instrument is commonly used for CQI-9 daily endothermic generator and furnace atmosphere checks. Using the included chart, operators can easily verify the control variable, carbon potential CP% or dew point, and make live corrections if necessary.
The DP2000 is light, portable and engineered for industrial environments. The battery typically lasts for eight hours and recharges quickly, and the rugged enclosure is built specifically for the heat treating environment.
| Standard range | -17 to 27 °C (0 to 80 °F) |
|---|---|
| Display | Digital LED |
| Accuracy and repeatability | +/- 0.5 °C (+/- 1 °F) |
| Resolution | +/- 0.5 °C (+/- 1 °F) |
| Zero and span drift | +/- 0.5 °C (+/- 1 °F) maximum |
| Operating temperature range | -17 to 49 °C (0 to 120 °F) |
| Output | 4-20 mA |
| Power | 115/240 VAC, 60 Hz |
| Size and weight | 279.4 mm H x 254 mm W x 177.8 mm L, 3.6 kg |
Applications
The probe measures and controls the carbon potential in controlled atmospheres, whatever the furnace design.
Enquiry
We reply within one working day, with a configuration and a quotation.

Portable infrared analyser measuring CO, CO2 and CH4 for verifying, optimising and troubleshooting furnace and generator atmospheres.

Portable infrared analyser measuring CO, CO2, CH4 and hydrogen for verifying, optimising and troubleshooting furnace atmospheres.

Portable low range dew point system for accurate and reliable verification of gases such as hydrogen, nitrogen and argon.