eFlo 2.0 Standard

Flow meters

eFlo 2.0 Standard gas flow measurement and control up to 350 mbar

DesignationeFlo 2.0 Standard

Measures and controls the flow of common process gases up to 350 mbar, with pressure and temperature compensation and calibration that can be certified in place.

  • Integrated communications over Modbus RS485 (RTU) and Ethernet (TCP)
  • Pressure and temperature compensation for a precise flow calculation
  • Flow Meter View software and a mobile interface for configuration
  • Available with an electronic valve, with or without control
  • Analogue control and feedback for data acquisition
  • Direct and remote setpoint control
  • Built-in high and low flow alarms
  • Flow totalising
  • Compact footprint
  • Onboard datalogging
  • NIST traceable calibration
  • USB and Bluetooth configuration tools
  • Mobile friendly and web based remote configuration
  • Flow calibration certifiable in place to CQI-9 requirements
  • Digital display with an easy to use touch pad and an optional touchscreen
  • SCADA integration: current flow, totalised flow, setpoint and cost calculation
  • Power required24 V DC at 400 mA
  • Accuracy±4%
  • Turndown ratio6:1
  • Gas temperature limits0 °C to 65.6 °C
  • Ambient temperature limits0 °C to 65.6 °C

Opis

SSi supplies flow measurement and control technology built for the harshest industrial environments. The eFlo 2.0 is the newest electronic flow measurement instrument line and, like the earlier eFlo models, it drops into existing control systems, which makes tracking and monitoring gas flows easier than ever and allows manual flow meters to be replaced without reworking the panel.

The meter is available in several configurations: with a motorised automatic control valve, with a manual control valve, without a control valve, and as a totaliser only. Depending on the model ordered, eFlo offers a digital display with a touch keypad, direct and remote setpoint control with built-in alarms, Modbus communications, digital and analogue I/O, USB and Ethernet connectivity, onboard datalogging and mobile device support.

Flow is derived from the differential pressure of the gas across a purpose designed orifice in the flow assembly, with pressure and temperature compensation applied to the calculation, and the instrument adds diagnostic information, flow rate and pressure alarms and a flow totaliser.

Dane techniczne

Power required24 V DC at 400 mA
Accuracy±4%
Turndown ratio6:1
Gas temperature limits0 °C to 65.6 °C
Ambient temperature limits0 °C to 65.6 °C
Flow output signal (linear)4-20 mA
Max. output signal load500 Ω
Input control signal (linear)4-20 mA
Response time1 to 10 seconds
CommunicationsRS485, Ethernet, USB
Communications protocolModbus RTU, Modbus TCP, EtherNet/IP
Flow meter pressure limit350 mbar max.
Pipe fitting1 1/4 in NPT
GasesNitrogen, hydrogen, ammonia, dissociated ammonia, argon, CO2, CO, methane, natural gas, propane, oxygen, air, endothermic and exothermic gas and others

Applications

It works where the atmosphere decides the quality of the case

The probe measures and controls the carbon potential in controlled atmospheres, whatever the furnace design.

Furnace types

01Annealing
02Carburising
03Endothermic gas generators
04Nitriding
05Sintering

Enquiry

Ask about this product

ProducteFlo 2.0 Standard gas flow measurement and control up to 350 mbar, eFlo 2.0 Standard
Podaj imię i nazwisko.
Podaj nazwę firmy.
Podaj poprawny adres e-mail.
Podaj poprawny numer telefonu.
Wybierz proces.
Napisz kilka słów o zastosowaniu.
Zgoda jest wymagana, żeby odpowiedzieć na zapytanie.
Fields marked * are required.

Enquiry sent

We reply within one working day, with a configuration and a quotation.

From the same group

Whole group

Technical advice

We will match the equipment to your process

Describe the process and the furnace, and we will reply with a proposed configuration and a quotation.

1 / 3eFlo 2.0 Standard gas flow measurement and control up to 350 mbar
eFlo 2.0 Standard gas flow measurement and control up to 350 mbar